RobustelGoRuggedM1000ProUserGuide
RT_M1000Pro_UG_v01.01 27.12.2011 33/59
Confidential
(e.g.Rebootok!).
Note:Onlysupportte xtformatSMS.
Note:
1. TimeformatforTimerebootis24hours.
2. ThephonenumbersforCallandSMSfunctioncanbesetinPhoneBooktab.
3. TheCallerIDmustbewrittenininternationalformat,startingwith +followedbythecountrycode.
4. IfyouleaveCallerIDblank,themodemwillrebootwithanyincomingcall,whichmaycauseunexpectedissue.
ItishighlyrecommendsettingtheCallID.
3.2.10 DI
Type Logic0(OFF) Logic1(ON)
Drycontact ClosetoGND open
ThistabdescribestheDigitalInputsettings.
Networks
Item Description Default
Mode
Modereferstothestatusofadigitalinputchannel.
SelectedfromOFF,ON,OnChange,EventCounterandNull.
OFF:issatisfiedforaslongasDIremainsoff
ON:issatisfiedforaslongasDIremainson
OnChange: triggering alarm when DI trigger the related action
whetheritisONorOFF
EventCounte r: undereventcountermode
Null:DIdisabled
Null
Filtering
Softwarefilteringisusedtocontrolswitchbounces.
Inputfrom0to10000ms.
0
CountTrigger
AvailablewhenDIunderEventCountermode.
Inputfrom0to30000.(0=willnottriggeralarm)
0