Robustel GoRugged M1000 Pro V2 User Guide
RT_M1000 Pro V2_UG_v01.00 23.11.2012 34 / 49
Confidential
3.2.13 Reboot
Since cellular network is not as stable as fixed line, M1000 Pro V2 supports various auto reboot function to keep
gateway working 24x7 without hang up.
Reboot
Note: This function is available under both “Config Mode” and “Normal Mode”.
Tick the Time checkbox to allow gateway auto reboot with preset time
schedule every day, support maximum 3 time schedule/day (e.g.
07:00, 11:00 and 23:30 every day).
Tick the Call checkbox to allow gateway auto reboot with incoming
call from specified Caller ID (phone number).
The Caller ID (phone number) should be specified in Phone Book tab
by inputting the phone number and tick Call Reboot checkbox.
Set the Phone Group which was allowed to reboot the gateway by
call.
Tick the Enable SMS Reply checkbox to allow gateway send reply short
message after auto reboot by Call Reboot from specified Caller ID (e.g.
Reboot ok!).
Note: Only support text format SMS.