1.3 Specifications
Cellular Interface
Standards: GSM/GPRS/UMTS
GPRS: max. 86 kbps (DL & UL), class 10
UMTS: max. 384 kbps (DL & UL)
Frequency: GSM 850/900/1800/1900 MHz
UMTS 850/1900 MHz or 900/2100
CSD: Up to 9.6 kbps
SIM: 1 x (3V & 1.8V)
Antenna Interface: SMA Female
Serial Interface
Number of Ports: 1 x DB9 Female
Serial Standards: RS232 or RS485
ESD Protection: 15KV
Baudrate: 1200bps to 115200bps
RS-232: TxD, RxD, RTS, CTS, GND
RS-485: Data+ (A), Data- (B), GND
USB Interface
Number of Ports: 1 x USB port for configuration
Standards: Mini USB
System
LED Indicators: 2 tri-color LED indicators, RUN, 3 level RSSI
Real Time Clock: Built-in real time clock
Watchdog and Timer: Built-in watchdog and timer
Software
IP protocols: PPP, TCP, UDP, ICMP, DDNS, SNTP, Telnet
Serial Port: TCP client/server, UDP, Modbus RTU to Modbus TCP, Virtual COM (COM port redirector)
RobustLink: Centralized M2M management platform
Power Supply and Consumption
Power Supply Interface: 2-pin 3.5mm pluggable terminal block
Input Voltage: 6 to 18 VDC
Power Consumption: Idle: 50-60 mA @ 12 V
Data Link: 100 to 200 mA (peak) @ 12 V
Physical Characteristics
Housing & Weight: Plastic, 105g
Dimension(L x W x H): 75 x 85 x 28 mm
Installation: 35mm Din-Rail or wall mounting or desktop