Robustel GoRugged R3000 User Guide
RT_UG_R3000_v.2.0.0 17.01.2014 55 / 131
Confidential
DO @ DI/DO
Item
Description
Default
Enable
Click to enable DO.
Disable
Alarm Source
Digital Output initiates according to different alarm source.
 s can be one or
more.
DI Alarm: Digital Output triggers the related action when there is alarm from Digital
Input.
SMS Control: Digital Output triggers the related action when receiving SMS from
the number in the phone book.
Call Control: Digital Output triggers the related action when receiving phone call
from the number in the phone book.
Null
Alarm On Action
Digital Output initiates when there is an alarm.

OFF: Open from GND when triggered.
ON: Short contact with GND when triggered.
Pulse: Generates a square wave as specified in the pulse mode parameters when
triggered.
ON
Alarm Off Action
Digital Output initiates when alarm recovered.

OFF: Open from GND when triggered.
ON: Short contact with GND when triggered.
Pulse: Generates a square wave as specified in the pulse mode parameters when
triggered.
ON
Status When Power
On
Specify the Digital Output status when power on.

OFF: Open from GND.
ON: Short contact with GND.
ON
Keep On (s)
Available when digital output Alarm On Action/Alarm Off Action status is ON, input
the Digital Output keep on status time.
Input from 0 to 255 seconds. (0=keep on until the next action)
0